Homepage
Products
Contact Us
About
Applications
Italiano
Vortex Tubes
Vortex Cooler Enclosure Coolers
Cold Air Guns
Micro Lubrication Cold Air Gun
Round Transvectors
Curtain Transvectors
Ionizing Curtain Transvector
Blower Driven Airknife
Blower Driven Airknife for Drying Bottles
Energy Saving Nozzles and Jets
Sprayvectors
Cold Pump Air Conditioner
Hand-E-Vac
Personal Air Conditioners
Dual-Force Vac
Vortex Enclosure Coolers Sizing
Download Vortex Enclosure Cooler - Sizing & Selection Worksheet
Cabinet dimensions
Height
Enter the height of the cabinet in inches
Width
Enter the width of the cabinet in inches
Depth
Enter the depth of the cabinet in inches
Internal temperature now
Enter the internal temperature of the cabinet in Fahrenheit. If unknown, go to the "Dissipated Heat in Watts" box
Ambient temperature now
Enter the temperature of the surrounding air in Fahrenheit. If unknown, go to the "Dissipated Heat in Watts" box
Desired internal temperature
Enter the temperature in Fahrenheit that you would like to maintain inside of the cabinet
Worst case ambient
Enter the highest surrounding temperature in Fahrenheit that the cabinet will be exposed to
If internal and ambient temperatures are unknown, use dissipated heat in watts
Dissipated heat in Watts
If you don't know the internal temp and ambient temp, you need to obtain the dissipated watts rating for each component inside of the cabinet. This can usually be obtained from the manufacturer of the components. Keep in mind, this is not the total energy consumption of the components, but the amount of energy that is lost in the form of heat
Temp. Rise Due To Solar Radiation if enclosure is exposed to direct sunlight
Cabinet color
Not at direct sunlight
White
Cream
Yellow
Light gray
Medium gray
Dark gray
Black
National aluminum or Stainless steel
Additional BTU's provided by fan(s) if the cabinet is fan cooled
SCFM
If your cabinet is fan cooled, enter the total SCFM rating(s) of fan(s) that are used to pull air through the cabinet. If not fan cooled, leave this box blank.
Temperature of air entering the enclosure
If your cabinet is fan cooled, enter the temperature in Fahrenheit of the air entering the enclosure. If not fan cooled, leave this box blank
Temperature of air exiting the enclosure
If your cabinet is fan cooled, enter the temperature in Fahrenheit of the air exiting the enclosure. If not fan cooled, leave this box blank
[